If you’ve ever stood at the edge of a well, staring down into the dark, wondering how far your deep well pump needs to go to work right, you’re not alone. When I first started selling deep well pumps a dozen years ago, I thought the answer was as simple as “lower it until it hits water.” That changed when a farmer 20 miles outside of town called me at 2 a.m. in the middle of a drought, yelling that his pump wouldn’t pull enough water to fill his cattle troughs. Turned out, he’d dropped it just past the visible water line in the well, not accounting for the gap between that line and the actual usable water table. That mistake cost him three days of parched cattle and a new pump seal—all because we’d skipped a few key calculations that make all the difference for deep well setups. Deep Well Pump

Today, as someone who’s installed, troubleshooted, and sold deep well pumps to farmers, homeowners, and small industrial operations across the region, I’m still surprised how many people get this part wrong. It’s not just about shoving the pump as far down the hole as it will go. It’s about balancing three non-negotiable numbers: the static water level, the drawdown level, and the minimum submergence your specific pump model needs. Get those right, and your pump will run efficiently, last twice as long, and never leave you stranded when you need water most. Mess them up, and you’ll be dealing with clogged impellers, overheated motors, or even a pump that burns out entirely before its first birthday.
Let’s start with the basics you can measure right now, no fancy equipment required. The static water level is the distance from the top of the well casing to the water surface when no one is pumping. If your well is 100 feet deep, and the water sits 40 feet down when nothing’s running, that’s your static level. Next is drawdown: that’s how much the water drops when your pump is running. Every pump pulls water, so the level will fall a little while the pump works. For most residential wells, drawdown is 10 to 20 feet, but if you’re pumping 10 gallons a minute for a large farm, that number can jump to 30 or more, especially during dry seasons.
This is where the 2 a.m. farmer went wrong. He had a static level of 55 feet, but his pump’s drawdown was 25 feet. That meant when the pump ran, the water dropped to 80 feet. He’d installed his pump at 65 feet, so half the time it was sucking in air instead of water. That’s why his pressure tank never topped off, and his pump made that terrible, grinding noise that means imminent failure.
Now, the minimum submergence number—this is the part most people forget. Every deep well pump (and I don’t care if it’s a submersible pump or a jet pump, though submersible is far more common for deep wells) has a rule: it needs at least 5 to 10 feet of water above it at all times when running. That’s to keep the pump’s impellers cool and prevent them from sucking air, which causes those annoying pressure spikes and impeller clogs. Some industrial models need even more—up to 15 feet. If your pump runs dry for even a few minutes, you’re looking at a repair bill of a few hundred dollars, easy.
So let’s do the math for that farmer, using real numbers from his well. Static level: 55 feet. Drawdown: 25 feet. Minimum submergence for his 5 HP farm pump: 8 feet. Add those up: 55 + 25 + 8 = 88 feet. He’d installed his pump at 65 feet, which was 23 feet short. No wonder it was failing. That fix took two hours and half a tank of gas, and he didn’t have to replace anything else.
But wait—what if your well is deeper, or the water table fluctuates? I worked with a homeowner last year who had a well that hit a static water level at 120 feet, but during the spring thaw, that level rose to 95 feet, and in late summer, it dropped to 135 feet. That’s a 40-foot swing, so you can’t just install based on the high or low end alone. We went with a pump that had an adjustable motor mount, so he could winch it up 10 feet in the dry season and lower it back down in the spring. That’s a little extra work, but way cheaper than a new pump every two years.
Another common mistake: installing the pump too close to the bottom of the well. You might think deeper is better, but no—wells have sediment at the bottom, especially older ones with limestone or sandstone bedrock. Lowering your pump too far lets that silt and sand get sucked into the impeller. Over time, that grit wears down the pump’s parts, cuts its efficiency, and reduces its lifespan by half. I’ve seen pumps fail in 18 months because someone dropped them right on the well bottom. A good rule of thumb here: leave 5 to 10 feet of gap between the pump’s inlet and the well bottom. That’s enough to keep sediment out without leaving too much empty space.
Now, let’s talk about different types of deep well pumps, because the depth rule changes a little depending on what you’re using. Submersible pumps, which are the most popular for wells over 25 feet deep, need the full submergence buffer I mentioned earlier. They sit right in the water, so cooling is less of an issue than with jet pumps, but sediment is still a big risk. If you have a shallow well or a deeper well that’s lined with PVC (no sediment buildup), you can get away with a smaller submergence gap, but never less than 5 feet.
Jet pumps, on the other hand, are installed at the top of the well, not down in the water. For deep well jet pumps, the maximum suction lift is about 25 feet. That means you can’t place the jet assembly more than 25 feet above the static water level, otherwise it won’t pull water at all. If your static level is 50 feet down, you need a different type of deep well jet pump with a deeper ejector, not a standard shallow-well jet. A lot of people mix these up, and end up with a pump that can’t pull water from more than 20 feet, even if their well is 100 feet deep.
I also get asked all the time: “Can I just use a longer pipe to lower the pump if my well is extra deep?” The short answer is, maybe, but don’t guess. Every pump has a maximum depth rating. A standard 1 HP submersible pump is rated for up to 100 feet, a 2 HP can go to 150, and industrial models can handle 500 feet or more. If you try to run a 100-foot rated pump at 120 feet, it’ll overheat because the motor is working harder than it’s designed to, and the extra length of pipe creates friction that reduces water flow. I had a guy last year who tried to stretch a 100-foot pump to fit his 110-foot well, and it burned out in a week. He thought he saved money by not buying a deeper pump, but he ended up paying twice as much for a replacement.
So how do you actually measure all this for your own well? Let’s break it down step by step, no fancy tools needed. First, grab a tape measure and a weight tied to a string. Lower the weight into the well until it touches the water—you’ll feel a tug when it breaks the surface. Mark the string at the top of the well casing, then pull it up and measure from the weight to the mark. That’s your static water level. Second, when the pump is running, wait 10 minutes, then do the same test. The difference between the two measurements is your drawdown. Third, check your pump’s manual for its minimum submergence—most brands list this in the specs, and if you don’t have the manual, just stick to 8 feet as a safe number for residential use. Then, add static + drawdown + submergence, and that’s your minimum pump depth. Add 5 feet extra for the sediment gap at the bottom, and you’ve got your sweet spot.
Let me give you a real example from a client I had in Iowa last summer. His well was 180 feet deep. Static water level: 125 feet in the spring, 140 feet in the fall. Drawdown when pumping 15 GPM: 18 feet. Minimum submergence for his 2 HP submersible pump: 8 feet. Sediment gap: 5 feet. So his minimum depth in spring: 125 + 18 + 8 + 5 = 156 feet. In fall: 140 + 18 + 8 + 5 = 171 feet. We recommended a 180-foot rated pump, which he installed at 160 feet in the spring and could lower to 175 feet in the fall. He’s had no issues for 10 months now, and his water pressure has stayed consistent.
Now, some people will tell you “just lower it as far as possible,” but I’m here to tell you that’s bad advice. I’ve seen wells where the water level drops 30 feet in a single summer drought—if your pump is sitting at 170 feet, and the water level drops to 190, that’s 20 feet of dry pump, and you’re back to the 2 a.m. failure scenario. It’s better to have a little gap in the wet season so you can adjust when the water drops.
Another thing to consider: your power supply. If your well is deeper than 50 feet, you’ll need a 230-volt circuit for most submersible pumps, not 110. Trying to run a deep well pump on 110 volts will make it work harder, overheat, and fail faster—this is another reason installing it too deep can backfire. The pump’s motor is already working against the water pressure from deep down; skimping on voltage just adds unnecessary stress.
I’ve also had homeowners come to me saying they installed a new pump last month and their water flow is weak. When I ask where they put it, they say “20 feet above the bottom.” Half the time, that’s the problem—their static level is 50 feet, drawdown is 15, so they’re only giving the pump 5 feet of submergence instead of the 8 it needs. A quick adjustment to the depth, and their flow goes from 5 GPM to 12 GPM. It’s not always a big, expensive fix; sometimes it’s just lowering the pump a few feet.
If you’re tackling this project yourself, there are a couple of safety tips I can’t skip. First, well water can have dangerous gases like methane or hydrogen sulfide, especially in older wells. Never lean over the well opening for more than a few seconds, and consider using a gas detector before you lower anything in. Second, never work alone. Lowering a pump on a string or pipe can be heavy, and if it slips, it can fall and cause injury. Third, make sure your well casing is secure. If it’s rusted or cracked, dropping a pump down the hole can damage it, so call a well driller first to check the casing if you’re unsure.

At the end of the day, getting the pump depth right is all about knowing your well, your pump, and how the two work together. It’s not a one-size-fits-all number—what works for your neighbor might not work for you, because their well’s water level, pump type, and usage are different. If you’re not sure how to calculate any of these numbers, or you’re tired of dealing with pumps that die every year, I’m here to help. I’ve spent 12 years learning the ins and outs of deep well pumps, and I can walk you through measuring your well, picking the right pump, and getting the depth just right so you don’t have to deal with those 2 a.m. panic calls.
Pressure Gauge References
- U.S. Environmental Protection Agency. Private Wells: Know Your Groundwater. 2022
- National Ground Water Association. Deep Well Pump Installation and Maintenance Guidelines. 2021
- Pump Industry Association. Submersible Pump Performance Standards for Groundwater Wells. 2020
- Iowa State University Extension. Deep Well Pump Sizing and Depth Calculations. 2019
- Texas A&M AgriLife Extension. Agricultural Water Well Design and Pump Installation. 2021
Taizhou Hanner Machinery Co., Ltd.
Taizhou Hanner Machinery Co., Ltd. is one of the leading deep well pump manufacturers and suppliers in China. We warmly welcome you to wholesale hot selling deep well pump from our factory. All customized products are with high quality and competitive price.
Address: Southeast Industrial Accumulation, Songmen Town, Wenling City, Zhejiang, China
E-mail: kathy@cnhanner.com
WebSite: https://www.hannerpump.com/